» Description
» Specification
» Photos
» Prospect
|
Products > Battlefield Systems > TAFIOS-B
AUTOMATIC DETECTOR OF CHEMICAL AND RADIOACTIVE CONTAMINATION
Technical specification
Functions
- Detection and measurements of the concentration of chemical contamination, classification of CWA/ITA groups
- Detection of immediate radiation resulting from a nuclear explosion
- Detection and measurement of delayed radiation following a nuclear explosion
- Detection of nuclear EMP
- Optical indication of contamination level exceeding a preset threshold
- Control of executive devices protecting the crew from contamination hazard
Detected chemical contamination
- Vapours of nerve chemical warfare agents (sarin, soman, tabun, Vx)
- Vapours of blister chemical warfare agents (sulphur mustard gas, nitrogen mustard gas, lewisite)
- Industrial toxic agents (chlorine, ammonia)
Gamma radiation dose rate range
- Measurement range
- Alarm threshold (factory preset) |
from natural background to 10° Gy/h
50° µGy/h (other upon request) |
| Gamma radiation dose range |
0° µGy - 20 Gy. |
Immediate radiation and nuclear EMP
detection range |
10km |
| Ionization chamber radiation source |
Ni-63, 100 MBq activity |
| 100 MBq activity |
9000 h, max. 2 years |
Military standard compliance
|
MIL-STD 810F, MIL-STD 461E |
| Data transmission interfaces |
RS232, RS485 |
| Operating temperature |
-30°C to 60°C |
| Storing temperature |
-40°C to 70°C |
| Power supply voltage |
16 to 32 V DC |
| Power consumption |
max. 100 W |
Dimensions (L x W x H):
- main unit
- control panel |
380 mm x 230 mm x 170 mm 90 mm x 120 mm x 90 mm |
Weight:
- main unit
- control panel |
ca. 15 kg
ca. 1.5 kg |
|
|