Technical specification

Functions

  • Detection and measurements of the concentration of chemical contamination, classification of CWA/ITA groups
  • Detection of immediate radiation resulting from a nuclear explosion
  • Detection and measurement of delayed radiation following a nuclear explosion
  • Detection of nuclear EMP
  • Optical indication of contamination level exceeding a preset threshold
  • Control of executive devices protecting the crew from contamination hazard

Detected chemical contamination

  • Vapours of nerve chemical warfare agents (sarin, soman, tabun, Vx)
  • Vapours of blister chemical warfare agents (sulphur mustard gas, nitrogen mustard gas, lewisite)
  • Industrial toxic agents (chlorine, ammonia)
Gamma radiation dose rate range

- Measurement range
- Alarm threshold (factory preset)


from natural background to 10° Gy/h
50° µGy/h (other upon request)
Gamma radiation dose range 0° µGy - 20 Gy.
Immediate radiation and nuclear EMP
detection range

10km
Ionization chamber radiation source Ni-63, 100 MBq activity
100 MBq activity 9000 h, max. 2 years
Military standard compliance
MIL-STD 810F, MIL-STD 461E
Data transmission interfaces RS232, RS485
Operating temperature -30°C to 60°C
Storing temperature -40°C to 70°C
Power supply voltage 16 to 32 V DC
Power consumption max. 100 W
Dimensions (L x W x H):
- main unit
- control panel

380 mm x 230 mm x 170 mm
90 mm x 120 mm x 90 mm
Weight:
- main unit
- control panel

ca. 15 kg
ca. 1.5 kg


 
 
   
   
   





































RADWAR SA, 30 Poligonowa St., 04-051 Warsaw, Poland, phone: (+48) 22 813 0715, fax: (+48) 22 813 4884,